DSC-BRAIN USER GUIDE · REFERENCE

Alert catalogue

Every alert the brain can raise, its default severity, what it means and the first thing to check.

  verified for 9.0.0 · firmware train 8.2.0.0

  last verified 2026-09-17 · mirrored 2026-09-15

Severity is the default; change it per alert under Settings › Alerts. The emergency failsafe cannot be turned off. An alert not listed here takes warn. Names are the titles the dashboard shows; entity ids are shown for the entity inspector and rules. Runoff EC above feed, Runoff pH swinging and Drying room too humid fire only once their thresholds are set; Grow alert sensitivity (Off, Relaxed, Moderate, Strict; Off by default) on Settings › Root or Settings › Climate sets all three.

Critical

Alert Entity Means First check
Smoke detected binary_sensor.dsc_smoke_detected A smoke alarm bound to a hazard role is sounding; raised at once, no hold Go to the room; if there is fire or smoke you cannot trace, leave and call emergency services
Gas detected binary_sensor.dsc_gas_detected A gas alarm bound to a hazard role reports a leak Switch nothing in the room; shut the gas or cylinder valve, ventilate from outside
Carbon monoxide binary_sensor.dsc_co_detected A CO alarm bound to a hazard role is sounding (or reports 50 ppm or more) Get everyone into fresh air; do not go back in until it clears
Emergency failsafe binary_sensor.dsc_hub_emergency_failsafe The hub no longer trusts its climate sensors; risky loads off Sensor fault alerts below; hub sensors and wiring
Climate sensor fault binary_sensor.dsc_hub_climate_sensor_fault A tent DHT is not answering or is implausible The sensor and its cable
Root-zone probes binary_sensor.dsc_hub_root_zone_sensor_fault The mat loop has no trustworthy probe Probe faults; mat votes
2×4 dark violation binary_sensor.dsc_clone_dark_period_violation Lamp on inside the protected dark hours Manual hold; plug schedules
Dehumidifier not keeping up binary_sensor.dsc_dehumidifier_ineffective_suspect Ran without moving RH Tank, filter, the right plug bound
Heater / Heat-mat / Humidifier / Dehumidifier relay not following binary_sensor.dsc_<appliance>_relay_mismatch Plug state disagrees with hub demand Plug reboot; another controller
Climate sensor stuck binary_sensor.dsc_hub_climate_sensor_stuck A tent reading has not changed for too long The sensor
Hub not reporting binary_sensor.dsc_hub_not_reporting Hub silent for 3 min Hub Wi-Fi, power, fallback hotspot
Heater plug not reporting binary_sensor.dsc_heater_not_reporting Heater plug dropped off (its relay may still be closed) The plug on the LAN
Climate reading rejected binary_sensor.dsc_hub_climate_reading_rejected A reading outside the clamps; the ladder would act on it The sensor, then Settings › Sensors clamps
Drying room too humid binary_sensor.dsc_dry_mold_risk A zone in the Dry role has air at or above the dry-room RH you set — mould risk on hanging flower Dry run card on Climate; bring RH down, check dense buds

Warn

Alert Entity Means
Safety alarm silent binary_sensor.dsc_hazard_alarm_not_reporting A smoke, gas or CO alarm bound to a hazard role has not reported for 26 hours (battery, or off the Zigbee network)
4×8 / 2×4 humidity out of band binary_sensor.dsc_4x8_rh_out_of_band, dsc_2x4_rh_out_of_band RH outside the Want band
4×8 / 2×4 VPD out of band dsc_4x8_vpd_out_of_band, dsc_2x4_vpd_out_of_band VPD outside the band
4×8 / 2×4 temperature out of band dsc_4x8_temp_out_of_band, dsc_2x4_temp_out_of_band Temperature outside the band
Heat mat / Humidifier / Dehumidifier plug not reporting dsc_heatmat_not_reporting, dsc_humidifier_not_reporting, dsc_dehumidifier_not_reporting Plug dropped off the LAN
Probe 1 / 2 not reporting dsc_probe1_not_reporting, dsc_probe2_not_reporting Probe dark for 15 min; steering withheld
Probe 1 / 2 channel fault dsc_probe1_channel_fault, dsc_probe2_channel_fault A frozen, railed or drifting EC, pH or soil-temperature channel
Tank EC / pH out of range, Tank too warm dsc_tank_ec_out_of_range, dsc_tank_ph_out_of_range, dsc_tank_water_too_warm Reservoir readings from the water tester
Runoff EC above feed binary_sensor.dsc_runoff_ec_shift_high A plant's latest runoff EC is above its input by at least the threshold (salts building)
Runoff pH swinging binary_sensor.dsc_runoff_ph_shift_high A plant's latest runoff pH differs from its input by at least the threshold
Jar needs a burp binary_sensor.dsc_cure_jar_rh_high A cure jar's RH is at or above the burp-now line
Cure fridge off band binary_sensor.dsc_cure_temp_out_of_band The cure zone's air is outside the fridge band plus tolerance

Info

Alert Entity Means
Light catch-up active binary_sensor.dsc_hub_light_catchup_active The hub is making up lit hours
Reduced kit binary_sensor.dsc_reduced_kit Fewer devices in service than the kit expects
Plant specs incomplete binary_sensor.dsc_plant_specs_incomplete A roster plant is missing catalog fields
Intake over exhaust; AC capacity missing; Dehumidifier rate 0; Humidifier rate 0; Heater spec 0 dsc_plant_specs_* Configuration nags about equipment ratings
Jar sensor silent binary_sensor.dsc_cure_jar_silent A jar's Zigbee puck stopped reporting (weak link inside a fridge)

Also on the desk

  • Banners raised by automation rules, with the tone the rule chose.
  • REMINDER cards from journal reminders.
  • DHT disagreement pairs the zones in one card.