Found 2026-09-08 while diagnosing the over-pressure report. The check was abs(total_intake – total_exhaust) where total_intake is the sum of the intake allocated sensors (Sigma-exhaust-capacity split by intake fan pct) and total_exhaust is the sum of the exhaust allocated sensors (Sigma-intake-capacity split by exhaust fan pct). The two are computed from opposite bases, so the comparison never tested the rig — it compared each side against the other’s mirror. Rebased on capacity vs capacity and given the net pressure in its attributes. Note the chip is still gated on Climate (not a live alarm), so this was invisible.
Journey event · 14 Sep 2026
binary_sensor.dsc_flow_mass_balance_ok compared two mutually-derived allocations, so it could never fail honestly
Found 2026-09-08 while diagnosing the over-pressure report. The check was abs(total_intake - total_exhaust) where total_intake is the sum of the intake allocated sensors (Sigma-exh
● state copied from the tracker, never improved
● event date 2026-09-14
| Event date | 2026-09-14 |
| Version found | |
| Version fixed | |
| Expected kit firmware | |
| Release file | |
| SHA-256 | |
| Served count | |
| Source | https://app.notion.com/3d52b4cda37081caa37bf1668503398d |
Empty rows are honest
A blank cell means the tracker has no value for it. Nothing on this page is filled in to look complete.