DSC-BRAIN USER GUIDE · TROUBLESHOOTING

Known limitations and honest out-of-service

Things the kit tells you it cannot do on this release, and why they are shown rather than hidden.

●  verified for 9.0.0 · corrected for 9.8.9 on 2026-10-01

●  first mirrored 2026-09-15

Limitation What you see Status
The 4×8's plug-switched lamp has no light sensor Hours counted from a bound lamp plug's on-time (Got · Lamp plug: power at the socket, not light), else from the photoperiod window By hardware; bind a plug to Lamp plug · 4×8
Cancel catch-up forgives only the current cycle A Cancel catch-up toggle appears on the Light desk while a catch-up runs; tomorrow's schedule is unchanged and the lamp is not switched off by it By design
Brain does not write hub demand "Brain proposes, hub applies" By design today. The planner works out its plans alongside; no class has been handed to the brain, and the hub's own control still runs the room
Timed runs on kinds of device the new engine does not switch The receipt reads Planned only, nothing was sent Until that kind of device is handed over
AC relay (F-001) and clone mister (F-002) Tiles read OOS, out of service (F-001 on hold) / (F-002 on hold); settings rows stay honest Hardware on hold indefinitely
Probes 3 and 4 Not in the kit; add a third probe under Devices if you own one Retired from the kit
Push notifications to a phone Built, off by default Not set up on the reference rig
People and roles Single owner; power users get advanced rows and profiles instead By design
°F, light theme Not offered By design
Tuya and Zigbee plugs have no hub cut-out Hold last state when the brain stops By design; climate legs stay on Sonoffs
USB flash from the shipped image sees no ports Empty Port list; use the ESPHome dashboard or a workstation Container has no USB passthrough
Bluetooth LE sensors Listed and identified on Settings › Devices › Zigbee (Bluetooth sensors); once you bind one, its readings feed your climate readings Bind a sensor to use it
Safety cut-off reach Only the heater, the heat mat and lamp plugs are switched off; fans, humidifier, dehumidifier and hub-dimmed lamps are left alone. Off unless an alarm carries the Safety cut-off task; nothing comes back on until you release it By design
Tents and rooms beyond this rig This rig: room + 4×8 + 2×4 Design goal
Other smart-home software The brain owns every connection itself; there is no bridge to other software By design

The rule behind the list: an honest out of service or dashed row beats a toggle that does nothing.

DSC-Brain user guide · Known limitations and honest out-of-service · this page is edited on the site; the Notion original was retired after the mirror